Home / Safety and verification
Safety and verification
Safety and verification: what you can check
We would rather show you documents than ask for your trust. Here is how to use hydrogen at home with common sense, which documents we publish and who is responsible for the product in the EU.
Documents
Download the documentation before you buy
The technical datasheet, the safety sheet and the user manual, in your language. You can read them before you buy.
Gas purity and quality
Verification of flow, purity and absence of ozone
We verify flow, purity and absence of ozone with an independent laboratory. We will publish the full report here.
- Independent laboratory reportFlow, hydrogen purity and absence of ozone.Coming soon
Tests and conformity
Tested to European standards
VIVAIR Pro has been tested by an independent laboratory to these standards and passed every test. The full reports are part of its technical file and are available to the authorities.
- Electrical safety · Low Voltage Directive 2014/35/EUEN IEC 60335-1:2023+A11:2023, safety of household appliances. Report LST250598095LR, 30/05/2025: passed.
- Electromagnetic compatibility · Directive 2014/30/EUEN IEC 55014-1:2021, EN IEC 55014-2:2021, EN IEC 61000-3-2:2019+A1:2021+A2:2024 and EN 61000-3-3:2013+A1:2019+A2:2021. Report LST250598095ER, 30/05/2025: passed.
- Restricted substances · RoHS 2011/65/EU and (EU) 2015/863Lead, cadmium, mercury, hexavalent chromium, PBBs, PBDEs and four phthalates, within the limits. Report AZT250528086C-E0, 19/06/2025: passed.
- REACH · Regulation (EC) 1907/2006The 247 substances of very high concern (SVHC) on the candidate list, below 0.1%. Report AZT250528087C-E0, 10/06/2025: passed.
- Materials in contact with water · Regulations (EC) 1935/2004 and (EU) 10/2011Lid, tank and silicone tube: overall and heavy-metal migration within the limits. Report AZT250528088C-E0, 09/06/2025: passed.
Hydrogen at home, with common sense
Four simple rules to use it with peace of mind
Ventilated room
Use VIVAIR in a room with ventilation.
Away from flames
Keep it away from flames, candles, cigarettes and heat sources.
Uncovered
Do not cover it while it is running.
It switches itself off
The device stops when the programmed time is up.
Maintenance
Little maintenance: suitable water, a monthly clean and your cannula
VIVAIR Pro needs very little maintenance: always use suitable water, clean the tank once a month, drain it before moving it or if you will not use it for a while, and change your cannula from time to time.
- Purified water, alwaysReverse-osmosis or distilled, with TDS ≤30 ppm. Never tap or mineral water.
- Clean the tank once a monthA few minutes, following the steps in the manual.
- Empty it before moving or storing itIf you are going to move it or will not use it for a while.
- Nasal cannula with condenserConsumable: replace it every 3 months. Also in packs of 5, 10 and 20.7,90 €
Something not right?
Open a support request and we reply within 24 business hours
From your account or by writing to info@vivair.eu. No endless forms or call centres.
- 01
Open a support request
From your account, with your order number, or by email to info@vivair.eu.
- 02
We reply within 24 working hours
We review your case and tell you the next steps.
- 03
We sort it out
With our technical service in the EU and the 3-year warranty of your VIVAIR Pro.
Still have questions? We'll answer them.
A real advisor calls you, in Spanish and with no obligation.
Still have questions? We'll answer them.
Write to us and we reply within 24 business hours.